BA II Plus basics: decimal places, clearing memory, reset, and AOS vs Chain
To show 4 decimals press 2NDFORMAT. (FORMAT), type 4, press ENTER, then 2NDQUITCPT (QUIT). The calculator keeps all digits; only the display changes.
Decimal places
| Step | Keys | Display shows | What it does |
|---|---|---|---|
| 1 | 2÷3= | 0.67 | 2 ÷ 3 with 2 decimals. |
| 2 | 2NDFORMAT. | DEC= 2.00 | FORMAT: DEC shows the current number of decimals. |
| 3 | 4ENTER | DEC= 4.0000 | Set 4 decimals (9 = floating, as many as needed). |
| 4 | 2NDQUITCPT | 0.0000 | QUIT: back to the calculator, which shows 0. |
| 5 | 2÷3= | 0.6667 | The same division, now with 4 decimals. |
Use 2 decimals for money; 4 or more for rates and exam answers. 9 means floating: every digit that fits.
AOS vs Chain: why 3 + 4 × 5 gives 35
After a reset the BA II Plus works in Chn (chain) mode: each operation is done as soon as you press the next one, left to right. In AOS it follows the usual order (multiplication before addition).
| Step | Keys | Display shows | What it does |
|---|---|---|---|
| 1 | 2NDFORMAT. | DEC= 2.00 | FORMAT worksheet. |
| 2 | ↓↓↓↓ | Chn | Down to the calculation method: Chn (chain). |
| 3 | 2NDSETENTER | AOS | SET switches to AOS (algebraic order). |
| 4 | 2NDQUITCPT | 0.00 | QUIT. |
| 5 | 3+4×5= | 23.00 | Multiplication first: 3 + 20. |
Got a different number?
These are the wrong results this example gives when one thing is off. Each one was produced by replaying the mistake on our engine.
| You see | Why | Fix |
|---|---|---|
| 35.00 | The calculator is in Chn (chain) mode: it works left to right, so (3 + 4) × 5. | Switch to AOS as above, or use parentheses: 3+(4×5)=. |
The mode stays as set until you change it or reset. In Chn mode, parentheses still work.
Storing a number
| Step | Keys | Display shows | What it does |
|---|---|---|---|
| 1 | 1.0525STO1 | 1.05 | Store a number in memory 1 (M0 to M9). |
| 2 | CE|CCE|C | 0.00 | Clear the display. |
| 3 | RCL1 | 1.05 | Recall it (all digits are kept). |
STO and a digit store the display in one of ten memories; RCL and the digit bring it back with every digit, which is better than retyping a rounded number.
Clearing: which key clears what
| Keys | What it clears |
|---|---|
| CE|C | The number being typed or an error message; a second press clears the calculation in progress. Not the TVM values, not the worksheets. |
| 2NDCLR TVMFV | CLR TVM: N, I/Y, PV, PMT and FV (P/Y, C/Y and BGN are kept). |
| 2NDCLR WORKCE|C | CLR WORK: the worksheet you are in (cash flows, bond, amortization...). |
| 2NDMEM0 then 2NDCLR WORKCE|C | The ten memories M0 to M9. |
| 2NDRESET+|−ENTER | RESET: everything, including P/Y, BGN, decimals and AOS. |
Reset
| Step | Keys | Display shows | What it does |
|---|---|---|---|
| 1 | 2NDRESET+|− | RST ? 0.00 | RESET asks for confirmation. |
| 2 | ENTER | RST 0.00 | Everything back to factory settings: memories, worksheets, P/Y = 1, END, 2 decimals, Chn. |
A reset is the quickest way to a known state before an exam or when nothing adds up. Afterwards set what you need again (decimals, AOS, P/Y). See BA II Plus for the CFA exam.
Related
How we checked this page: every display above comes from replaying the keys on a tested engine, and the final answer is compared with an independent formula. How we check every answer.